Table 2 Mean DSC and the distance between the COMs of structures

From: The application of PET-CT to post-mastectomy regional radiation therapy using a deformable image registration

  Axillary artery Axillary vein Clavicle Coracoid process Humeral head
DSC*      
mean ± 95% CI 0.43 ± 0.15 0.39 ± 0.20 0.85 ± 0.10 0.72 ± 0.20 0.77 ± 0.20
Distance between the COMs (lateral direction) (mm)      
mean ± 95% CI 11.0 ±7.6 18.4 ± 11.8 2.8 ± 3.7 1.4 ± 3.6 4.8 ± 17.0
Distance between the COMs (sup.-inf. direction) (mm)      
mean ± 95% CI 3.7 ± 2.2 3.7 ± 3.0 2.7 ± 4.8 2.4 ± 5.2 5.9 ± 17.5
Distance between the COMs (ant.-post. direction) (mm)      
mean ± 95% CI 3.7 ± 2.9 5.2 ± 4.1 1.7 ± 2. 1.9 ± 2.7 4.5 ± 7.4
Distance between the COMs (3 dimensional) (mm)      
mean ± 95% CI 13.0 ± 7.1 20.2 ± 11.2 4.4 ± 6.3 3.7 ± 6.7 9.5 ± 25.0
  1. * Dice similarity coefficient, Confidence interval, Centers of mass.